Technology
                                                                              Main economic and technical indexes of 100 t/d lime kiln
                                                                               
                                                                              【Details description】

                                                                              1. Effective volume: 200m3
                                                                              2. Height: 34m
                                                                              3. Maximum inner diameter: 3.8m
                                                                              4. Daily output of single furnace: 100T
                                                                              5. Heating consumption: 125~135kg, standard coal/ton lime
                                                                              6. Utilization factor: 0.6~0.8
                                                                              7. Activity degree of lime: (ml):180~280
                                                                              8. Lime CaO(%):85-92
                                                                              9. Underfiring and overburning rate of lime (%): 5-10
                                                                              10. Limestone consumption (t/t. lime): 1.7
                                                                              11. Dust emission index after water-bath dust removal (mg/Nm3): 25-45
                                                                              12. Power consumption: 9~10 degree/ton lime
                                                                              13. Operator: 2